State the difference between unity P.F wattmeter and low P.F wattmeter.

2 Answers

 
Best answer
The primary difference between a unity power factor (P.F.) wattmeter and a low power factor wattmeter lies in their design and application. Here’s a detailed comparison:

### 1. **Purpose and Application**

- **Unity P.F. Wattmeter:**
  - Designed specifically for measuring power in circuits where the power factor is close to unity (i.e., nearly 1).
  - Commonly used in resistive loads or where the phase angle between voltage and current is minimal.
  - Ideal for applications where power factor correction is not a concern.

- **Low P.F. Wattmeter:**
  - Designed to accurately measure power in circuits with low power factors (i.e., where the power factor is significantly less than 1).
  - Used in circuits with inductive or capacitive loads where the power factor is low.
  - Important in industrial applications where power factor correction is crucial for efficiency.

### 2. **Design and Construction**

- **Unity P.F. Wattmeter:**
  - Often simpler in design as it assumes the voltage and current are nearly in phase.
  - The measuring mechanism (like the movement or coils) is calibrated assuming a power factor of 1.

- **Low P.F. Wattmeter:**
  - More complex design to account for the phase difference between voltage and current.
  - Typically includes additional features or compensation mechanisms to accurately measure power when the power factor is low.

### 3. **Accuracy and Calibration**

- **Unity P.F. Wattmeter:**
  - High accuracy in measurements when used in circuits with a power factor near 1.
  - Less emphasis on compensating for phase differences.

- **Low P.F. Wattmeter:**
  - More accurate in measuring power under low power factor conditions.
  - Often calibrated or adjusted to account for the phase shift between voltage and current.

### 4. **Measurement Mechanism**

- **Unity P.F. Wattmeter:**
  - Generally uses a simpler measuring mechanism since the voltage and current are nearly in phase.

- **Low P.F. Wattmeter:**
  - May employ advanced mechanisms or compensation techniques to correctly measure power when there is a significant phase difference.

### 5. **Usage Context**

- **Unity P.F. Wattmeter:**
  - Suitable for home appliances, heating elements, or any application where the load is predominantly resistive.

- **Low P.F. Wattmeter:**
  - Used in settings with motors, transformers, or other inductive loads where power factor correction is needed for efficiency.

In summary, while a unity power factor wattmeter is designed for ease of use in nearly resistive loads, a low power factor wattmeter is tailored to handle the complexities of measuring power where the phase angle between voltage and current is significant.
0 like 0 dislike
Certainly! Here's a comparison between a unity power factor (P.F) wattmeter and a low power factor (P.F) wattmeter:

### Unity Power Factor Wattmeter:
- **Design Purpose:** Specifically designed for measuring power in circuits where the power factor is close to or equal to unity (1).
- **Usage:** Typically used in circuits with resistive loads where the voltage and current are in phase.
- **Accuracy:** Provides accurate readings when the power factor is unity. The internal mechanism and scale are optimized for this condition.
- **Measurement Principle:** Generally uses a simpler design as the power factor correction is not needed. It can be an electrodynamic or moving-coil type wattmeter.
- **Scale Calibration:** The scale is calibrated to read directly in watts for a power factor of 1.

### Low Power Factor Wattmeter:
- **Design Purpose:** Designed to measure power in circuits where the power factor is significantly less than unity (i.e., circuits with inductive or capacitive loads).
- **Usage:** Suitable for systems with a low power factor, such as in industrial applications where reactive power is significant.
- **Accuracy:** Compensates for the effects of low power factor to provide accurate readings. It often includes a correction mechanism to account for phase differences between voltage and current.
- **Measurement Principle:** More complex design compared to unity P.F wattmeters, often incorporating additional correction circuitry or features to handle phase angle differences. It may be an electrodynamic, moving-coil, or digital wattmeter.
- **Scale Calibration:** The scale may be designed to correct for power factor and may not directly read in watts; users may need to apply a correction factor based on the power factor.

In summary, unity power factor wattmeters are designed for simplicity and accuracy in purely resistive circuits, while low power factor wattmeters include additional features or corrections to accurately measure power in circuits with significant phase differences.
0 like 0 dislike

Related questions

For the tariff of 125/kVA of maximum demand and 3.00 per unit consumed; load factor = 50%, find overall cost/unit at i) unity power factor ii) 0.8 p.f consider maximum demand = 10 kVA.
Answer : To calculate the overall cost per unit (kWh) for the given tariff structure, we need to use the following steps: ### Given Data: - **Tariff for maximum demand**: ₹125 per kVA of maximum demand - **Tariff per unit consumed ... = **₹3.35** 2. **At power factor 0.8**: Overall cost per unit = **₹3.43**...

Show More

An industrial consumer charged with the scheduled tariff of Rs.250 /kVA per month for maximum demand and 150 paisa per unit consumed for load factor of 60% and 80%. Find overall cost per unit at i) unity P.F. ii) 0.9 P.F. consider maximum demand of 50 kVA.
Answer : To determine the overall cost per unit for an industrial consumer based on the given data, we need to calculate the cost considering both the maximum demand and the energy consumption. Here's how we can ... 1.93/kWh The power factor does not alter the overall cost per unit directly in this case....

Show More

A 250/125 V, 5 KVA single-phase transformer has primary resistance of 0.2 Ω and reactance of 0.75 Ω. The secondary resistance is 0.05 Ω and reactance of 0.2 Ω. Determine its regulation while supplying full load on 0.8 leading P.F.
Answer : To calculate the voltage regulation of a transformer, we use the formula: \[ \text{Voltage Regulation} = \frac{V_{nl} - V_{fl}}{V_{fl}} \times 100 \] Where: - \( V_{nl} ... is approximately **-4.88%**. The negative sign indicates that the voltage rises under leading power factor conditions....

Show More

A 3 phase line of 4 km length delivers 4000 kW at a p.f of 0.8 lagging to a load the resistance and reactance per km of each conductor are 0.2 Ω and 0.5 Ω respectively if the voltage at the supply end is maintained at 11 kV. Calculate the received end voltage and efficiency of line.
Answer : To calculate the **received end voltage** and the **efficiency** of the transmission line, we need to follow these steps: ### 1. **Given data:** - Load power (\( P_L \)) = 4000 kW = 4000 10³ W - Power factor ... approx 10.02 \, \text{kV} \) - **Efficiency of the line**: \( \eta \approx 99.76\% \)...

Show More

Power input to a 400V, 60Hz, 6 pole 3 φ I.M. running at 1140 rpm. is 40Kw. at 0.8 p.f. lag. Stator losses are 1000W. and friction windage losses are 2000W. Calculate - i) Slip ii) Rotor copper loss
Answer : To solve this problem, we'll follow these steps: 1. **Determine the synchronous speed (\(N_s\)) of the induction motor.** 2. **Calculate the slip (\(s\)) of the induction motor.** 3. **Determine the rotor copper ... ] ### Summary - **Slip (\(s\))**: 0.05 or 5% - **Rotor Copper Losses**: 1950 W...

Show More
Welcome to Electrical Engineering, where you can ask questions and receive answers from other members of the community.