### Synchrophasor-Based Protection in Wide Area Protection
**Synchrophasor-based protection schemes** are advanced systems that use **Phasor Measurement Units (PMUs)** to enhance power system protection. These systems form a key part of **Wide Area Protection Systems (WAPS)** or **Wide Area Monitoring, Protection, and Control (WAMPAC)** schemes, which monitor and protect power grids over large geographical areas.
To understand how these systems function, it's important to break down both synchrophasors and wide-area protection, and then see how they interact.
---
### Key Concepts
1. **Synchrophasors and PMUs**:
- A **synchrophasor** is a time-synchronized measurement of an electrical waveform, which includes both the magnitude and phase angle of the voltage and current at a specific point in the power system.
- **Phasor Measurement Units (PMUs)** are devices that measure these synchrophasors with very high accuracy, typically using GPS signals to ensure that the measurements from different locations are synchronized in real time.
- This synchronization allows for a unified, global view of the electrical behavior across different parts of the power grid.
2. **Wide Area Protection (WAP)**:
- **Wide Area Protection** refers to the concept of protecting the power system on a large scale (across regions, states, or even countries). Traditional protection systems rely on local information from individual substations or areas, which may not be sufficient for detecting system-wide issues.
- **WAP** enhances the ability to detect, mitigate, and respond to disturbances that span large distances and may involve multiple elements of the grid (e.g., lines, generators, substations).
---
### Function of a Synchrophasor-Based Protection Scheme in Wide Area Protection
Synchrophasor-based protection schemes enhance **Wide Area Protection** in the following ways:
#### 1. **Real-Time Monitoring of System Stability**
- **Function**: Synchrophasors provide real-time data on voltage, current, and phase angle from across the power grid. This enables system operators to continuously monitor the grid’s stability, detecting abnormal conditions like frequency or voltage oscillations, power swings, or angular instability.
- **Benefit**: Since synchrophasors are synchronized with GPS time stamps, the data from different locations can be compared instantaneously. This enables faster detection of instabilities over large areas, which may not be visible to local protection systems.
#### 2. **Improved Fault Detection and Location**
- **Function**: With the synchronized data from multiple PMUs, the system can accurately locate the point of a fault (e.g., line fault or transformer failure) by analyzing the differences in phase angles and voltage/current magnitudes across different parts of the system.
- **Benefit**: Faster and more accurate fault detection helps operators to isolate the problem quickly, reducing the risk of cascading failures, where a local fault causes a series of widespread outages.
#### 3. **Wide-Area Disturbance Detection**
- **Function**: Synchrophasors help detect wide-area disturbances that local relays may not catch. For example, oscillations in frequency or power can spread across the grid. A synchrophasor-based system can identify and react to such disturbances across vast distances before they cause severe damage.
- **Benefit**: The system can trigger remedial actions, such as load shedding or generator tripping, to stabilize the grid before a blackout occurs.
#### 4. **Dynamic Protection Settings**
- **Function**: Synchrophasor data allows for **adaptive protection schemes**. These systems adjust protection settings in real-time based on the current grid conditions. For example, during normal operation, protection settings may be more sensitive, but during a fault or disturbance, they might adjust to prevent nuisance tripping.
- **Benefit**: This dynamic approach increases the reliability of the grid and ensures that protection systems remain effective under changing conditions, like fluctuating loads or varying power flows.
#### 5. **Prevention of Cascading Failures**
- **Function**: One of the biggest threats in large power systems is a **cascading failure**, where an initial fault (e.g., a line outage) triggers a chain reaction of failures that leads to a widespread blackout. Synchrophasor-based systems detect the conditions that could lead to such a failure (e.g., angular separation between areas of the grid) and initiate control actions to prevent them.
- **Benefit**: By acting before the problem spreads, the system can prevent large-scale blackouts, ensuring grid stability.
#### 6. **Post-Event Analysis and System Recovery**
- **Function**: After a disturbance or outage, the synchrophasor data provides high-resolution information on how the event unfolded. This helps engineers to understand the root cause of the event, how it propagated, and how the system responded.
- **Benefit**: This detailed post-event analysis can improve future protection schemes and prevent similar events from occurring.
---
### Components of a Synchrophasor-Based Protection Scheme
1. **Phasor Measurement Units (PMUs)**:
- These are deployed across the power grid at strategic locations (e.g., substations, transmission lines, generators).
2. **Communication Network**:
- A fast and reliable communication infrastructure is essential to transmit the synchronized data in real-time from PMUs to control centers.
3. **Wide-Area Monitoring System (WAMS)**:
- This central system gathers data from PMUs, analyzes it in real-time, and coordinates protection actions (e.g., sending trip signals or control commands).
4. **Centralized Protection and Control System**:
- This system processes the wide-area data, detects disturbances, and makes decisions to protect the grid, such as tripping breakers, adjusting voltage settings, or redistributing power flow.
5. **Remedial Action Schemes (RAS)**:
- These are automated systems that take corrective actions based on synchrophasor data, such as load shedding, generation control, or dynamic line rating adjustments.
---
### Advantages of Synchrophasor-Based Protection in Wide Area Protection
1. **Faster Response Time**: Since synchrophasors provide real-time, synchronized data, the protection system can respond faster to disturbances than traditional methods.
2. **Better Situational Awareness**: Operators get a clearer picture of grid health across wide areas, enabling them to anticipate and mitigate potential issues before they escalate.
3. **Coordination Across Regions**: Unlike localized protection, synchrophasor-based systems enable coordinated actions across different parts of the power grid, enhancing overall grid security.
4. **Enhanced Reliability**: These systems improve the overall reliability of the grid by offering better fault detection, minimizing outages, and enabling faster recovery from disturbances.
---
### Conclusion
A **synchrophasor-based protection scheme** is essential for modern **wide-area protection** of power systems. By providing real-time, synchronized data across large geographical areas, it significantly enhances the ability to monitor, protect, and control the grid. These systems detect and respond to faults more quickly, help prevent cascading failures, and enable dynamic adjustments to ensure grid stability and reliability. As power grids become larger and more interconnected, synchrophasor-based protection is increasingly crucial in maintaining secure and stable electrical infrastructure.