What is full scale deflection of galvanometer?

2 Answers

 
๏ธ
Best answer
Full-scale deflection of a galvanometer refers to the maximum deflection of the needle or pointer in response to an electrical current passing through it. It indicates the highest amount of current that the galvanometer can measure and is typically expressed in milliamperes (mA) or microamperes (ยตA).

In practical terms, the full-scale deflection point helps users understand the sensitivity and range of the galvanometer. A galvanometer calibrated to show full-scale deflection at a specific current level will provide accurate readings for currents up to that level, beyond which the readings may become inaccurate or the device could be damaged.

The full-scale deflection can also depend on the specific design of the galvanometer, including the type of coil, the strength of the magnetic field, and the resistance in the circuit.
0 like 0 dislike
Full-scale deflection (FSD) of a galvanometer refers to the maximum deflection that the galvanometer's pointer can achieve when the maximum allowable current flows through it. Essentially, it indicates the upper limit of the galvanometer's measurement range.

### Key Concepts

1. **Galvanometer Basics**:
   - A galvanometer is an electromechanical device that detects and measures small electric currents. It typically consists of a coil suspended in a magnetic field, which experiences torque when current passes through it.

2. **Deflection**:
   - The deflection of the galvanometer's needle is proportional to the current flowing through the coil. As the current increases, the needle moves further from its resting position.

3. **Full-Scale Deflection (FSD)**:
   - FSD is defined as the current required to move the pointer to the maximum scale reading (usually the extreme right on a dial). For example, if a galvanometer is calibrated to show full-scale deflection at 1 mA, it means that a current of 1 mA will cause the pointer to reach its maximum position.

### Importance of FSD

- **Calibration**: Knowing the FSD allows for proper calibration of the instrument, ensuring accurate readings.
- **Sensitivity**: The FSD gives an indication of the sensitivity of the galvanometer; a lower FSD current typically means higher sensitivity, allowing the instrument to detect smaller currents.
- **Design and Application**: Different applications require different FSD values. For example, sensitive laboratory equipment might use galvanometers with low FSD values, while industrial applications may require higher FSDs.

### Calculation of FSD

The FSD can be determined by the following formula, where \( k \) is the constant that relates current to deflection:

\[
I_{FSD} = \frac{V}{R + r}
\]

- \( I_{FSD} \): Current for full-scale deflection
- \( V \): Voltage applied across the galvanometer
- \( R \): External resistance connected in series with the galvanometer
- \( r \): Internal resistance of the galvanometer

By understanding the concept of full-scale deflection, one can effectively utilize galvanometers in various electrical measurements and ensure they operate within their specified limits.
0 like 0 dislike

Related questions

A single phase wattmeter rated for 500 V; 5 A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?
Answer : To find the multiplying factor (MF) of a wattmeter, we need to understand that it helps scale the measured power reading from the wattmeter to match the actual power in the circuit. The multiplying factor is typically ... W}} = 2.5 \] Thus, the multiplying factor of the wattmeter is **2.5**....

Show More

A moving coil instrument gives full scale deflection of 24 mA. When a P.D. across if is 108 mV. Find the value of โ€“ (i) Series resistance for full scale deflection of 400 V. (ii) Find the power consumption.
Answer : To solve this problem, we need to find the series resistance required for full-scale deflection at a higher voltage and the power consumption of the moving coil instrument. ### Given Data: - Full scale deflection current ... deflection of 400 V: **16662.17 ฮฉ** (ii) Power consumption: **2.592 mW**...

Show More

What is the full scale current of galvanometer?
Answer : Could you clarify what context you're referring to? Are you asking about a specific type of galvanometer, or do you want general information about its full-scale current?...

Show More

Why galvanometer shows zero deflection?
Answer : A traveling-wave tube amplifier (TWTA) is a specialized device used to amplify high-frequency signals, often in the microwave range. Here's how it functions: ### Basic Components 1. ** ... electron beam with a slow-wave signal, making it a crucial component in many advanced communication systems....

Show More

What is the formula for deflection of galvanometer?
Answer : The deflection \( \theta \) of a galvanometer is typically related to the current \( I \) passing through it and can be expressed using the formula: \[ \theta = k \cdot I \] where: - \( ... If you have a specific type of galvanometer or circuit in mind, let me know, and I can provide more details!...

Show More
Welcome to Electrical Engineering, where you can ask questions and receive answers from other members of the community.