For a **1.5-ton air conditioner (AC)**, choosing the correct wire size is crucial to ensure both safety and efficiency. The wire size depends on the power consumption of the AC unit, which is influenced by factors like voltage (usually 220V or 230V in many countries) and the current drawn by the AC. Hereβs a detailed breakdown:
### 1. **Current Draw of a 1.5-Ton AC:**
- A 1.5-ton AC typically consumes **1.5 kW to 2 kW** of power.
- The current draw can be calculated using the formula:
\[
\text{Current} = \frac{\text{Power (W)}}{\text{Voltage (V)}}
\]
Assuming a typical power consumption of **1.8 kW** and a voltage of **230V**, the current would be:
\[
\text{Current} = \frac{1800}{230} = 7.83A
\]
Hence, the AC unit will typically draw around **8 to 10 Amps** of current under normal operation.
### 2. **Recommended Wire Size:**
- For a load that draws about **8 to 10 Amps**, the recommended wire size is **2.5 sq. mm** (cross-sectional area) for copper wiring, as it is commonly used in many countries and can handle up to 20A of current safely.
- If you are using **aluminum wiring**, a slightly thicker wire is required due to the lower conductivity of aluminum. In that case, a **4 sq. mm** aluminum wire should be used to handle the same current.
### 3. **Voltage Drop and Wire Length:**
- If the distance between the power source and the air conditioner is relatively long (over 50 feet or 15 meters), a larger wire size (like **4 sq. mm copper**) may be required to minimize voltage drop.
- Voltage drop can reduce the efficiency of the AC and lead to overheating or damage to the compressor.
### 4. **Circuit Breaker:**
- To protect the circuit, the AC unit should be connected to a **16A or 20A** circuit breaker, depending on the exact power consumption of the AC.
### Summary:
For a **1.5-ton air conditioner**, the most common and appropriate wire size for copper is **2.5 sq. mm**, which is capable of handling the typical current drawn by the unit. If using aluminum wiring, a **4 sq. mm** wire would be recommended. Additionally, ensure that the circuit breaker is rated for **16A to 20A** to match the electrical load.