The purpose of a stator earth fault protection scheme using third harmonic voltage is to detect and protect against earth faults in the stator windings of a generator or transformer. Here's a detailed explanation of how it works and why it's used:
### Background
In electrical power systems, stator windings of generators and transformers can develop earth faults. These faults occur when there is an unintentional connection between the stator winding and the ground. Detecting these faults quickly is crucial for preventing damage and ensuring the safe operation of the equipment.
### Third Harmonic Voltage
The third harmonic voltage is a component of the voltage waveform that is three times the fundamental frequency. For instance, if the fundamental frequency is 50 Hz, the third harmonic frequency is 150 Hz. In a balanced three-phase system, the third harmonic voltages are naturally present and can provide valuable information about the system's condition.
### Principle of Third Harmonic Detection
1. **Generation of Third Harmonic**: Under normal operating conditions, third harmonic voltages are generated in the stator windings. When an earth fault occurs, the distribution of these harmonic voltages changes.
2. **Magnitude Change**: An earth fault alters the neutral point of the generator or transformer. This change affects the distribution and magnitude of the third harmonic voltage in the stator windings.
3. **Detection**: The third harmonic voltage protection scheme monitors the magnitude of the third harmonic voltage. A significant change or increase in this voltage typically indicates the presence of an earth fault.
### Why Use Third Harmonic Voltage?
1. **Sensitivity**: The third harmonic voltage protection is very sensitive to earth faults, even when the fault current is low. This sensitivity makes it effective in detecting faults that might not produce high fault currents.
2. **Selective Detection**: This scheme helps to distinguish between earth faults and other types of faults (like phase-to-phase faults) that do not affect the third harmonic component in the same way.
3. **Fast Response**: The detection system can provide a fast response to earth faults, which is crucial for protecting the equipment from damage and minimizing the risk of further complications.
4. **Neutral Shift Detection**: The third harmonic voltage scheme can also help in detecting neutral shift, which occurs when there is a significant change in the neutral point position due to an earth fault.
### Implementation
- **Measurement**: Specialized relays are used to measure the third harmonic voltage. These relays are designed to be sensitive to changes in the third harmonic component and can provide an alarm or trip signal when abnormal levels are detected.
- **Settings**: The protection scheme must be correctly configured with appropriate settings to ensure that it only responds to genuine faults and avoids false tripping.
In summary, a stator earth fault protection scheme using third harmonic voltage is an effective method for detecting earth faults in the stator windings. It leverages the unique characteristics of third harmonic voltages to provide sensitive and reliable fault detection, helping to protect electrical equipment and maintain system stability.