Explain the conditions for setting up negative phase sequence currents in an alternator. Draw the protective scheme to detect them and operate the CB.
0 like 0 dislike

Related questions

How does a negative sequence overcurrent protection scheme detect high resistance phase-to-phase faults?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does a negative sequence differential protection scheme detect turn-to-turn faults?

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

How does a negative sequence overcurrent protection scheme detect broken conductor faults?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

How does a negative sequence overcurrent protection scheme detect unbalanced faults?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

How does a current unbalance protection scheme detect open phase conditions in motors?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

How does a phase angle difference protection scheme detect out-of-step conditions?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

How does a current balance protection scheme detect open phase conditions?
Answer : A current balance protection scheme is commonly used in electrical power systems to detect faults, including open phase conditions. To understand how it detects an open phase, let's break down ... and the protection system will identify the imbalance, triggering a fault condition for an open phase....

View solution
0 like 0 dislike
3 views 1 answer
× Full Screen Image

Define the following terms with respect to protective relays: i) Relay time ii) Reset current iii) Plug setting multiplier iv) Time setting multiplier.

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

Explain the experimental set-up for the Newton’s rings formation with suitable diagram. Write conditions for dark and bright rings.

View solution
0 like 0 dislike
4 views 0 answers
× Full Screen Image

A three-phase transformer having a line voltage ratio of 0.4 kV/11kV is connected Star/Delta and protective transformers on the 0.4 kV side have a current ratio of 500/5. Calculate the ratio of ... on the 11 kV side. Draw a neat circuit diagram and indicate the given values at appropriate places.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

What is the purpose of a negative sequence differential protection scheme in generator-transformer units?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

What is the purpose of a negative sequence differential protection scheme in transformers?

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

What is the purpose of a negative sequence differential protection scheme in generators?
Answer : The purpose of a **negative sequence differential protection scheme** in generators is to detect and protect the generator from **unbalanced conditions** caused by faults, such as phase-to-phase faults ... of these faults, and ensures **safe operation** of the generator within the power system....

View solution
0 like 0 dislike
6 views 1 answer
× Full Screen Image

How does a voltage vector shift protection scheme detect islanding conditions?
Answer : In a voltage vector shift protection scheme, islanding conditions are detected by monitoring the phase angle of the voltage vector at the point of common coupling (PCC). Here's how it works: 1. ... and the DG system will change in the event of islanding, allowing for early detection and isolation....

View solution
0 like 0 dislike
3 views 1 answer
× Full Screen Image

What is the purpose of negative phase sequence protection in generators?

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

How does a negative sequence directional overcurrent protection scheme handle load unbalance?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does a negative sequence directional comparison scheme work?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does a negative sequence directional overcurrent protection scheme determine fault direction?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does a voltage dependent negative sequence overcurrent protection scheme work?
Answer : A **voltage-dependent negative sequence overcurrent protection** scheme is designed to protect three-phase electrical systems, particularly motors, from damage due to unbalanced conditions or phase faults like ... the system voltage is sufficiently high, it triggers a trip to protect the equipment....

View solution
0 like 0 dislike
4 views 1 answer
× Full Screen Image

Explain with a neat circuit diagram only the Scott connection scheme for the conversion of three-phase supply to two-phase supply. Name one application of the same.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

State and explain working of phase sequence indicator with suitable sketch.
Answer : A **Phase Sequence Indicator (PSI)** is a device used to determine the sequence of phases in a three-phase electrical system. The phase sequence indicates the order in which the three-phase supply ... system operation. Would you like a diagram or further details on any part of the explanation?...

View solution
0 like 0 dislike
3 views 1 answer
× Full Screen Image

How does a phase comparison protection scheme handle weak infeed conditions in teed circuits?

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

List different starting methods of three phase synchronous motor. Explain any one of them.
Answer : There are several methods to start a three-phase synchronous motor, and these methods are used to overcome the challenges of starting synchronous motors, as they require high starting torque. Some ... used because it allows the motor to start smoothly without the need for complex external equipment....

View solution
0 like 0 dislike
3 views 1 answer
× Full Screen Image

How does a phase discontinuity protection scheme detect broken conductors?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

Derive the torque equation of 3 φ I.M. under running condition.k) Explain production of R.M.F. in 3-phase I.M. when 3 φ supply is fed to it. Draw its phasor diagram.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

How does an adaptive overcurrent protection scheme adjust to changing system conditions?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does an adaptive distance protection scheme adjust to system conditions?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does a phase comparison protection scheme handle weak terminal conditions?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does a phase comparison protection scheme handle weak infeed conditions?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

Explain the concept of ground loops and how to avoid them.
Answer : A **ground loop** occurs when there are multiple grounding points at different electrical potentials in a system, creating a difference in voltage between them. This can cause unwanted currents to ... from potential ground loop currents, you can prevent most of the issues associated with them....

View solution
0 like 0 dislike
4 views 1 answer
× Full Screen Image

Define voltage regulation of an alternator. Explain synchronous impedance method for finding regulation of alternator.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image
0 like 0 dislike
2 views 0 answers
× Full Screen Image

What is the difference between negative sequence and zero sequence current protection?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

How does zero-sequence protection detect ground faults?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Define armature reaction in an alternator. Explain the effect of armature reaction at various power factors of loads of alternator.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Explain any six quality requirements for better protective relaying.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

What are the basic concepts of household wiring and explain them?

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

Classify various electric heating methods and explain them briefly.
Answer : Electric heating methods can be classified based on how they convert electrical energy into heat. Here are the main types: ### 1. **Resistive Heating (Joule Heating)** - **How it works:* ... method has its own set of applications based on factors like efficiency, speed, material type, and cost....

View solution
0 like 0 dislike
5 views 1 answer
× Full Screen Image

Draw single phase full wave mid-point converter for inductive load. Draw input and output waveforms for it.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

Explain the lighting scheme to be designed for each of the following (i) Special ward in hospitals (ii) Dentist’s Cabin.

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

Explain lighting scheme to be designed for each of the following (i) operation theatre in hospital (ii) general ward in hospitals.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

A 220V/22kV three-phase transformer is connected in star/delta. The protective transformers on the 220V side have a current ratio of 400/5. Calculate the CT ratio on the 22kV side.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

How does a vector shift relay detect islanding conditions?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

How does a voltage dependent overcurrent protection scheme adapt to different system conditions?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Draw vector diagram of loaded alternator at lagging power factor.

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

State the insulating materials used in motor. Write temperature class and withstand temperature ranges for them.

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

Draw the layout of a typical micro hydro scheme and describe potential locations of micro-hydro power plants in Maharashtra.

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

Draw and explain the block diagram of an instrumentation system.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

How does a negative sequence directional element enhance protection selectivity?

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

What is the purpose of negative sequence differential protection?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image
Learn Electrical Engineering the easy way at Electrical-Engineering.app – tutorials, tools, calculators, and video lessons for students, professionals, and beginners.

Subjects

29.4k questions

7.3k answers

7.8k users