A three-phase transformer having a line voltage ratio of 0.4 kV/11kV is connected Star/Delta and protective transformers on the 0.4 kV side have a current ratio of 500/5. Calculate the ratio of the protective transformers on the 11 kV side. Draw a neat circuit diagram and indicate the given values at appropriate places.
0 like 0 dislike

Related questions

A 220V/22kV three-phase transformer is connected in star/delta. The protective transformers on the 220V side have a current ratio of 400/5. Calculate the CT ratio on the 22kV side.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

A 3 phase line of 4 km length delivers 4000 kW at a p.f of 0.8 lagging to a load the resistance and reactance per km of each conductor are 0.2 Ω and 0.5 Ω respectively if the voltage at the supply end is maintained at 11 kV. Calculate the received end voltage and efficiency of line.
Answer : Let's break down the problem step by step and calculate the received end voltage and the efficiency of the line. ### Given Data: - Power delivered to the load, \( P = 4000 \, \text{kW} \) - Power factor, \( \text{p. ... voltage**: \( 10.43 \, \text{kV} \) - **Efficiency of the line**: \( 98.61\% \)...

View solution
0 like 0 dislike
4 views 1 answer
× Full Screen Image

A plant consists of two 10 MVA generators of reactance 18% each and two 5 MVA generators of 12% each. All are connected to bus bar to supply a load through three step up transformers of 8 MVA each having reactance of 8%. Determine fault MVA on HV side of any one transformer.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

What is the relation between line and phase values in a star and delta connected system?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Draw neat diagram of star-delta starter for three phase induction motor.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

A 500kVA distribution transformer having copper and iron losses of 5kW and 3kW respectively on full load. The transformer is loaded as shown below: Loading (kW) Power Factor (Lag) No. of hours 400 0.8 06 300 0.75 12 100 0.8 03 No load - 03 Calculate the all-day efficiency.
Answer : To calculate the all-day efficiency of the transformer, we need to consider the total energy output, the total energy input, and the losses over a 24-hour period. The transformer experiences two types of ... \] ### Final Answer: The all-day efficiency of the transformer is approximately **98.39%**....

View solution
0 like 0 dislike
3 views 1 answer
× Full Screen Image

Describe the control of a single lamp from three places. Draw the relevant circuit diagram.
Answer : To control a single lamp from three different places, we can use a **three-way switch** system. In this setup, we use three switches to control the lamp, which is typically used in large rooms or ... of **two-way switches** and **three-way switches**, with the proper connection of traveler wires....

View solution
0 like 0 dislike
2 views 1 answer
× Full Screen Image

Draw the single line diagram (layout) of 33/11 kV substation.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

State the relationship between line voltage & phase voltage and line current & phase current in a 3-phase star connected system.
Answer : In a 3-phase star (wye) connected system, the relationship between line voltage, phase voltage, line current, and phase current can be summarized as follows: ### 1. **Line Voltage and ... and currents behave in a 3-phase system, especially when configuring systems for different types of loads....

View solution
0 like 0 dislike
7 views 1 answer
× Full Screen Image

Explain Star and Delta connected three-phase balanced circuits.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

State the relationship between line voltage & phase voltage and line current & phase current in a 3-phase delta connected system.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

A single phase wattmeter rated for 500 V; 5 A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

Draw a circuit diagram for polarity test on a single-phase transformer.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

A 3 φ I.M. has synchronous speed of 250rpm and 4% slip at full load. The rotor has a resistance of 0.02Ω/ph and stand still reactance of 0.15Ω/ph. Calculate i) The speed at which max torque is developed. ii) The ratio of maximum to F. L. torque. iii) The ratio of maximum to starting torque.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

How do you calculate the appropriate wire gauge for a given current load?

View solution
0 like 0 dislike
6 views 0 answers
× Full Screen Image

What is the relationship between the line voltage and the phase voltage in a delta connected load?
Answer : In a delta-connected load, the relationship between the line voltage (\(V_L\)) and the phase voltage (\(V_\phi\)) is: \[ V_L = V_\phi \] ### Explanation: - **Line Voltage (\(V_L\))** is the ... line voltage is √3 times the phase voltage. So, in summary: - **Delta Connection**: \(V_L = V_\phi\)...

View solution
0 like 0 dislike
4 views 1 answer
× Full Screen Image

Describe the method of converting a three-phase to a two-phase transformer by neat diagram. State any two applications.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image
0 like 0 dislike
4 views 0 answers
× Full Screen Image

Draw a neat experimental setup to conduct OC test on a single-phase transformer.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

A 3-ph overhead line supported by 6 disc insulators, the potential across the unit is 11 KV. Assuming shunt capacitance between each Insulator and each metal link is of 1/5th of capacitance of insulator. Calculate:

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Explain control of a single lamp from four places. Draw the relevant circuit diagram.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

Which meter has a greater sensitivity and why? Meter A having a range of 0-10 V and a multiplier resistance of 18 kΩ and meter B with a range of 0-300 V and multiplier resistance of 298 kΩ? Both meter movements have a resistance of 2 kΩ.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

Explain with a neat circuit diagram only the Scott connection scheme for the conversion of three-phase supply to two-phase supply. Name one application of the same.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

What is the relation between power in 3 phase delta and star connected system?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

What is the relationship of line and phase voltages and currents in a delta connected system?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Why most of analog o/p devices having o/p range 4 to 20 mA and not 0 to 20 mA?
Answer : The main reason most analog output devices use a 4 to 20 mA range instead of 0 to 20 mA is to ensure reliable operation and easier detection of faults. Here's a breakdown of why 4- ... fault detection, and stability in signal transmission, which is why it's widely adopted in analog output devices....

View solution
0 like 0 dislike
4 views 1 answer
× Full Screen Image

Draw a neat labelled diagram of 3-phase electronic energy meter.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

Why is the transformer connected in delta Star?
Answer : A transformer is connected in a **delta-star (Δ-Y)** configuration for several practical reasons in electrical systems. Here's why it's commonly used: ### 1. **Step-down Voltage* ... single-phase connections. It offers benefits like voltage stability, load balancing, and better handling of faults....

View solution
0 like 0 dislike
5 views 1 answer
× Full Screen Image

Draw neat circuit diagram of (i) Feeder reactor and (ii) Generator reactor

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Draw the neat labelled diagram showing the controls available on front panel of CRO.
Answer : Sure! Here's a neat, labelled diagram of the front panel of a Cathode Ray Oscilloscope (CRO), along with a description of the controls typically found on it. ### **Diagram of Front ... you a solid understanding of the controls available on the front panel of a typical Cathode Ray Oscilloscope....

View solution
0 like 0 dislike
5 views 1 answer
× Full Screen Image

Draw wiring diagram for connection of one lamp controlled from two places. State the application of this connection.

View solution
0 like 0 dislike
0 views 0 answers
× Full Screen Image

State significance of earthing. Draw and explain pipe earthing. State the values of earth resistances for: (i) Substation (ii) Residential wiring (iii) H.T. Line (iv) L.T. Line.

View solution
0 like 0 dislike
5 views 0 answers
× Full Screen Image

Does a circle have 0 or 1 side?
Answer : A circle is often said to have **1 side**. This is because it's a continuous curve with no breaks or angles. So, while it doesn't have sides in the same way a polygon (like a triangle ... circle has 0 sides because it doesn't have straight edges, but mathematically, it's considered to have 1 side....

View solution
0 like 0 dislike
2 views 1 answer
× Full Screen Image

Draw the constructional diagram of LVDT. State its working principle. What is residual voltage? Explain with a neat diagram.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Draw the power flow diagram of three phase induction motor.

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

Explain the conditions for setting up negative phase sequence currents in an alternator. Draw the protective scheme to detect them and operate the CB.

View solution
0 like 0 dislike
4 views 0 answers
× Full Screen Image

Determine the power factor of an RLC series circuit with given values.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

Calculate the voltage necessary and current flowing through a dielectric heating system given specific parameters.
Answer : To calculate the voltage necessary and the current flowing through a dielectric heating system, we need to know the following parameters: 1. **Power required for heating** (P) - the power needed to heat the ... know if you have specific values you'd like to use, and I can help you calculate that!...

View solution
0 like 0 dislike
7 views 1 answer
× Full Screen Image

Draw the circuit diagram and phasor diagram of nominal T method of medium transmission line.
Answer : ### Nominal T Method of Medium Transmission Line In the **Nominal T method** of representing a medium transmission line, the series impedance (Z) is represented in the form of a "T", where the series impedance is placed in the middle of the ... | / | Is ----|...

View solution
0 like 0 dislike
2 views 1 answer
× Full Screen Image

Derive the expression of line current in terms of phase voltage in delta connection.

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image

A uniform illumination of 150 lux is to be obtained on the floor of a room measuring 15m x 15m by arranging electric lights suitably. Calculate the number of lamps and wattage of each ... lamp efficiency is 20 lumens/watt. Assume and write suitable values of constants required for this calculation.

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

What is the current in the RL circuit at a time t=0?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

Draw a neat labeled diagram of a neon sign tube and explain its working.

View solution
0 like 0 dislike
4 views 0 answers
× Full Screen Image

What are the advantages of star and delta connected systems?
Answer : Star and delta connections are two different ways to connect three-phase electrical systems, and each has its own advantages depending on the application. Here's a comparison: ### **Star Connection (Wye ... voltage step-up or step-down (via transformers), and delta used for power delivery to loads....

View solution
0 like 0 dislike
4 views 1 answer
× Full Screen Image
0 like 0 dislike
1 view 0 answers
× Full Screen Image

What is the formulae for delta and star connected system?
Answer : In electrical engineering, Delta (Δ) and Star (Y) connections refer to the way the windings of three-phase systems (like transformers and motors) are connected. Here are the key ... electrical systems and help in calculating voltages, currents, and impedances for different types of connections....

View solution
0 like 0 dislike
7 views 1 answer
× Full Screen Image

What is the difference between star connected load and delta connected load?

View solution
0 like 0 dislike
3 views 0 answers
× Full Screen Image

What is the formula for Delta and star connected system?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

What is the relationship between resistance connected in delta and equivalent star system?

View solution
0 like 0 dislike
1 view 0 answers
× Full Screen Image

What is the formula for Delta and Star connected system?

View solution
0 like 0 dislike
2 views 0 answers
× Full Screen Image
Learn Electrical Engineering the easy way at Electrical-Engineering.app – tutorials, tools, calculators, and video lessons for students, professionals, and beginners.

Subjects

29.4k questions

7.8k answers

7.8k users